The 51200 Transmitter Protection Assembly is installed at building locations where the 2000 and 4200 Cable Management Systems are installed. The 51200 is used at the cable origin in the cable vault or at the building entry point to safely originate two fiber optic cable armors.
The assembly is pre-wired in an enclosure to allow for the ease of installation at the building entry location. The assembly provides maximum duty total failsafe gas tube arrestors to provide high surge current protection and transient suppression. Induced Voltage Filters (IVF) are also included which consist of a tuned series pass network, which provide low impedance path to ground for induced 60 Hz AC current. Both Tone locating and cable monitoring signals pass by the assembly with little or no reduction in strength.
Inputs
CAPACITANCE: < 30 pF, line to ground
Protection
DC BREAKDOWN VOLTAGE: 265 – 600 VDC
IMPULSE BREAKDOWN: 500v (typical) at 100 v/µsec
750v (max.) at 100 v/µsec
IMPULSE CURRENT RATING: 40,000 A, 8×20 µs impulse, single cycle
AC CURRENT RATING (MOMENTARY): 10 A, 60Hz AC, 1s application
AC VOLTAGE RATING (CONTINUOUS): 175 VAC, 60Hz AC continuous
Induced Voltage Filtering
VOLTAGE REDUCTION RATION (TYPICAL): 7
(Zsource = 200O, IF = 500 ma)
MAXIMUM VOLTAGE (CONTINUOUS): 20 V, AC RMS
(5 MIN.): 250 V, AC RMS
CLAMPING VOLTAGE (TYPICAL): 15 V, AC RMS
IMPEDANCE (NOMINAL): 30 Ω @ 60 Hz
(I = 500 MA)
1200 O @ 30 HZ
7000 O @ 512 HZ
Dimensions:
14 x 12 x 7 in (35.6 x 30.5 x 17.8 cm)
Weight:
14.5 lbs (6.6 kg)
Simply fill out this form for your free Remote Cable Monitoring sample report!
Please fill out this form and a Norscan representative will be in contact to get started!
Please fill out this form and a Norscan representative will be in contact to get started!
Please fill out this form and a Norscan representative will be in contact to get started!