Product Catalogue

2316 Line Termination Unit

The 2316 Line Termination Unit (LTU) provides the required impedance path to ground for locator tones above 250 Hz while ensuring proper termination of the cable sheath for operation of cable sheath monitoring systems.

SKU: 2316LTU Category:
Description

The LTU also incorporates hybrid high voltage protection circuitry that provides a path to ground for high voltage transient surges. The Fixed Current model is used on cables with up to 20 terminations ensuring the tone reaches all terminations with equal signal strength. Fixed impedance LTU are also available for long cable runs with few terminations ensuring maximum signal strength reaches the terminations.

Features

Features

  • Provides the required termination impedance for locator tones
  • Provides high voltage transient surge protection
  • Provides the high impedance required for monitoring terminations
  • Rated for indoor/outside plant installation
  • Standard 16 gauge stranded copper leads
Specifications

Specifications

Inputs

CAPACITANCE: < 30 pF, line to ground
Protection

DC BREAKDOWN VOLTAGE: 265 – 600 VDC
IMPULSE BREAKDOWN: 750v (max) at 100 v/µsec
IMPULSE CURRENT RATING: 40,000 A, 8×20 µs impulse, single cycle
IMPULSE CURRENT RATING: 40kA, 8/20µs, > 1 operation
20KA, 8/20ΜS, > 10 OPERATIONS
1KA, 10/1000ΜS, > 400 OPERATIONS

Dimensions:
5 x 1.5 x 1.25 in (12.7 x 3.8 x 3.2 cm)
Weight:
0.5 lbs (0.23 kg)
Operating Temperature Range:
-58°F to +185°F (-50°C to +85°C)